nfpa 70e restricted approach boundary definition

NFPA 70E, the Standard for Electrical Safety in the Workplace, focuses on protecting employees and identifying the necessary requirement to free a workplace from electrical hazards. The Main Purpose of the Arc Flash Boundary Law The arc flash boundary law, also known as NFPA 70E, is the standards for electrical safety in the workplace. - Distances to maintain. TURN OFF THE POWER. Working inside the limited approach boundary is generally prohibited while alertness is recognizably impaired.

This is the outer boundary of the flash protection zone. inspections outside the restricted approach boundary N Q Panelboards & equip 240V up to 600V -Note 1 AFB= 3 Feet Note 1 - Reading panel meter while operating switch N Q Opening/Removing covers (to expose bare, energized parts) or Insulated cable examination with manipulation of cable 2 N Y Use NFPA 70E-2021 Table 130.4(E)(b) for direct current. The Restricted Approach Boundary (RAB) is the approach limit for qualified persons to exposed, energized electrical components where there is an increased likelihood of electric shock due to electrical arc-over combined with inadvertent movement. 130.5(B) Arc Flash Boundary: In addition to the existing definition of the arc flash boundary being the distance where the incident energy equals 1.2 cal/cm2, new language has been added permitting the arc flash boundary to be determined by Table 130.7(C)(15)(A)(b) or Table 130.7(C)(15)(B) when the requirements of the tables apply. The Limited Approach Boundary is defined as an approach limit at a distance from an exposed live part where a shock hazard exists. Determine which of the following among the NFPA 70E requirements relate to qualified person training, both generally and when such persons are permitted to work within the limited approach boundary. This is an attempt to clarify the 70E and make it easier for field workers to use. Restricted Approach Boundary - Includes Inadvertent Movement Adder Less than 50 Not Specified Not Specified Not Specified 50 to 300 10 ft 0 in. The typical nominal AC voltages that a maintenance person would be working on of 120, 208, 220, 240, 277, 380, and 480 all have a limited approach boundary of 42 inches.

/ 1.5 m 5 ft. 6 in. NFPA 70E 2009, 2012 & 2014 Updates Definition of Qualified . This isn't always feasible. The definition of a qualified electrical worker is explained as well as the knowledge and skills required a qualified electrical worker for to cross the Restricted Approach Boundary. Brief Description of Best Practice: NFPA 70E® - 2018 is recommended for approval across the DOE Complex as an upgrade to NFPA 70E® - 2015 in 10 CFR 851 Worker Safety and Health Plans (WSHP). Also, NFPA 70E 2000 requires that before a worker approaches exposed electric conductors or circuit parts that . 130.7(D)(1)(g) and 130.7(D)(1)(h) are revised to require the rubber insulating equipment and the plastic guard equipment to be rated for the voltage. Limited approach boundary is defined in Article 100 of NFPA 70E as "an approach limit at a distance from an exposed energized electrical conductor or circuit part within which a shock hazard exists." Therefore, in order to have a limited approach boundary, the cover(s) would have to be removed or the door(s) open, and there would have to be . The PAB was developed by the National Fire Protection Association (NFPA) as part of its 70e standard governing electrical safety. Best practice if for any unqualified person to stay 42" (3' 6") or more away from the hazard. - PPE required. Definition: An approach limit at a distance form an exposed live part within which there is an increased risk of shock, due to electrical arc over combined with inadvertent movement, for personnel working in close proximity to the live part. Where the employer can demonstrate that the task to be performed is infeasible in a de-energized state due to equipment design or . Restricted Approach Boundary. Reference: NFPA 70E Standard for Electrical Safety in the Workplace (2004 Edition) NFPA 70E states that when an employee is within the limited approach boundary or interacts with equipment in a manner that poses an increased likelihood of an arc flash, the equipment must be placed in an electrically safe work condition. This is presented in Table 4. Qualified workers within Limited Approach Boundary! Day One - NFPA 70E Chapter 1: Electrical Safe Work Practices . the new edition of NFPA 70E (2004): Limited Approach Boundary. When it is working on or near exposed live conductors and parts, NFPA 70E requires the following: 2. The restricted approach boundary is used to prevent injury due to electrical shock and arc flashes. Limited approach boundary . ELECTRICALLY SAFE WORKING CONDITION Steps to Establish Condition, Methods Used, PPE to be Worn During Procedure. Where the arc flash boundary is different than the limited approach boundary, barricades shall be placed at the farther boundary. When it is working on or near exposed live conductors and parts, NFPA 70E requires the following: 2. 3.0 m 3 ft 6in 1.0 m Avoid Contact 301 to 750 10 ft 0 in. / 1.0 m 3 ft. 6 in. The definition of a qualified electrical worker is explained in addition to the knowledge . An update to the 2012 version of Table 130.4 includes voltages up to 800kV. Limited shock approach boundary; Restricted shock approach boundary; Prohibited shock approach boundary; What is "incident energy"? Under NFPA 70E, there are three boundaries that are observed—limited approach, restricted approach, (the shock protection boundaries) and arc flash boundary. He has been instructing OSHA 10 hour, OSHA 30 hour, as well as Electrical Safe Work Practices/NFPA 70E classes since 2004. The limited, restricted and prohibited approach boundaries are based on the voltage of the energized equipment. Previously, EFCOG BP#193 determined that the use of the 2015 edition of NFPA 70E® is Definition Updated 130.2(B)(1) . . the Restricted Approach Boundary, as well as the approach boundary used for arc flash protection, the Arc-Flash Boundary. Restricted approach boundary is boundary near brought out live parts that may be . NFPA 70E defines the arc flash boundary as "…a distance from a prospective arc source within which a person could receive a second degree burn if an electrical arc flash were to occur.". NFPA 70E • Has grown to prominence in the past few years for rules on the hazards of "live work" - Traditionally it has been based on ac • NFPA 70E includes: - definitions - approach boundaries - calculations of incident energy - flash protection boundaries - hazard evaluation procedures Release of victims training Annually Electrical safety program audits every 3 years! true Protective shields, protective barriers, or insulating materials must generally be ? The Second Draft of this section eliminates the Prohibited Approach Boundary for the shock hazard. Attachment D, pg. •Definition . With this requirement, each qualified worker should determine the shock hazard by identifying the exposure to electrical parts, the nominal voltage of those parts, and shock PPE required for adequate protection within the determined minimum approach (or NFPA 70E restricted approach) boundary. He is well versed in the requirements of NFPA 70, the National Electrical Code®, and NFPA 70E®, the Standard for Electrical Safety in the Workplace. to avoid the effects of electrical hazards and inadvertent contact with exposed energized parts before entry into a confined or enclosed space. The employer is required to conduct hazard assessment in accordance with 29CFR1910.132(d)(1). / 1.0 m 5 ft. 6 in. NFPA 70E Reference Tables 2PAGE- 12-2018 130.5 ARTICLE 130 — WORK INVOLVING ELECTRICAL HAZARDS 70E-24 Shaded text = Revisions. The following definitions can be found in Article 100 of NFPA 70E: Below is a sample of NFPA 70E. Barricades shall be placed no closer than the applicable limited approach boundary given in Appendix A, (Table 130.4(D)(a) or Table 130.4(D)(b)) (NFPA 70E). The two lower-risk approach boundaries are the restricted approach boundary and the limited approach boundary (lowest risk). Looking further the restricted approach boundary is only 3 foot 3 inches. NFPA 70E 2018 has set the bar pretty high. Where there is a need for an unqualified person(s) to cross the Limited Approach Boundary, NFPA 70e dictates that a qualified person shall advise him or her of the possible hazards and continuously escort the . This training is conducted by Jerry Bennett, an authorized OSHA 502 Outreach Trainer. 1 OP 64.14 4/29/13 NFPA 70E Table 130.4 (C) (a) Approach Boundaries to Energized Electrical Conductors or Circuit Parts for Shock Protection fo r Alternating Current The definition of a qualified electrical worker is explained in addition to the knowledge and skills required for a qualified electrical worker to cross the Restricted Approach Boundary. Definitions of Boundaries and Spaces Flash Protection Boundary Restricted Approach Boundary ENERGIZED CIRCUITS When is Energized Work Acceptable Use of Energized Work Permits Determining Safe Boundaries .

The limited and restricted approach boundaries relate to electric shock hazards whereas the arc flash boundary is all about an arc flash hazard. Information shown in this table is an estimate - the actual arc . Shock PPE is required by NFPA 70E when body parts are within the restricted approach boundary. N = New material. Where there is a need for an unqualified person(s) to cross the limited approach boundary, a qualified person shall advise him or her of the possible hazards and continuously escort the unqualified person(s) while inside the limited approach boundary. Restricted Approach Boundary Shock Boundaries 150-750 V Qualified workers may enter restricted space only with appropriate protection 12" 42" 21 Approach Distances for Qualified Employees (Approach Boundaries- NFPA 70E Table 130.4(D)(a) The restricted approach boundary represents the minimum distance unprotected skin can The program provides a clear explanation of the two approach boundaries used for shock protection, the Limited Approach Boundary and the Restricted Approach Boundary, as well as the approach boundary used for arc flash protection, the Arc-Flash Boundary. limited approach boundary to the restricted approach boundary to clarify the difference between the use of barriers per 130.7(D) and barricades per 130.7(E). An approach limit at a distance from an exposed live part within which there is an increased risk of shock, due to electrical arc over and Under For example, at 480 volts, if personnel are troubleshooting within 18 inches of exposed energized parts, shock PPE should be worn ( rubber insulating gloves with leather protectors ).

Also included are the restrictions and exceptions for unqualified workers related to the various . enforce the NFPA 70E standard, OSHA considers the NFPA standard a recognized industry practice and the administration's field inspectors carry with them a copy of the NFPA 70E and use it to enforce safety proc edures related to arc flash. NFPA 70E SERIES 2015 NFPA 70E - Standard for Electrical Safety in the Workplace . inspections outside the restricted approach boundary N Q Panelboards & equip 240V up to 600V -Note 1 AFB= 3 Feet Note 1 - Reading panel meter while operating switch N Q Opening/Removing covers (to expose bare, energized parts) or Insulated cable examination with manipulation of cable 2 N Y